Of course, if the installation is made in violation of the technology and the system has got a lot of debris, the filter can not stop him. 7. Pipe fittings – to them connect copper pipes connecting the outer and inner blocks. 8. To broaden your perception, visit Peter Thiel. Protective cover quick release – closes the choke connections and terminals used to connect electrical cables.

In some models, the protective cover only covers the terminals, and Pipe fittings remain outside. Indoor unit air conditioner indoor unit comprises the following components: 1. Front panel – is a plastic grid, through which enters the air inside the unit. The panel is easily removed for Service air conditioning (filter cleaning, etc.) 2. Coarse filter – is a plastic mesh and is designed to delay big Dust, animal hair, etc. For normal operation of the air conditioner filter should be cleaned at least twice a month. 3.

Evaporator – radiator, which heats the cold Freon and its evaporation. Blown through the cooler air, respectively, is cooled. 4. Horizontal blinds – regulate air flow direction vertically. These blinds have the drive and their position can be adjusted by remote control. In addition, the shutters can automatically carry out the vibrational motion for uniform distribution of air flow around the room. 5. Flat panel – front panel mounted air conditioner indicators (LEDs), showing mode and signal conditioning on the possible faults. 6. Fine filter – is of different types: coal (removes odors), electrostatic (retards fine dust), etc. The presence or absence of fine filters no impact on job air conditioner has not. 7. Ventilator – a 3 – 4 speed. 8. Vertical blinds – are used to adjust the air flow horizontally. In the household air-conditioners position of these blinds can be adjusted manually. Ability to adjust with the remote control is available only in some models of luxury air-conditioners. 9. Drip tray (not shown) – is located under the evaporator and serves to collect the condensate (water, formed on the surface of a cold evaporator). From sump water is expelled through the drain hose. 10. The control board (not shown) – usually located on the right side of the indoor unit. On this board posted electronics unit with a central microprocessor. 11. Pipe fittings (not shown) – are located in the lower back of the indoor unit. They connect copper pipes connecting the outer and inner blocks.

Posted in General

Comments are closed.